Öppnas i en ny flik
Bruksanvisning

THEO MA1 Operatörshandbok

THEO ACADEMY · MA1 SERIES
OPERATOR TRAINING HANDBOOK
SAFE OPERATION OF THEO MA1 HAND-HELD LASER WELDERS
Training content according to Regulation (EU) 2023/1230 and ISO 11553-2:2026
MA1-35 · MA1-45 · MA1-65 · MA1 ULTRA
Edition 1.0 · 13 November 2026
by MAXPHOTONICS

About this handbook

INTRODUCTION

ABOUT THIS HANDBOOK

ONE PATH. EVERY OPERATOR. PROOF ON PAPER.

What to know, what to do, and how to prove it – for every MA1 operator.

This handbook structures the operator training for THEO MA1 series hand-held laser welding systems. It combines the MA1 operating manual with the THEO Safety, Application and Service workshops into one path that ends with a documented result: a trained operator, an activated machine and a signed training record.

1080 nm Invisible infrared laser radiation
CLASS 4 Laser product per EN 60825-1
118–282 m NOHD, depending on model
1 PERSON Operates the laser welder

SCOPE AND AUDIENCE

Machines THEO MA1-35, MA1-45, MA1-65 and MA1 ULTRA, each with the T1 wire feeder
Participants Operators at the end customer who will set up, operate and care for the MA1
Trainers THEO Academy, THEO application engineers and authorized THEO trade and service partners
Reference Operating manual “Serie MA1” (translation of the original operating manual), version 2.0
IMPORTANT
This handbook supports training. It does not replace the operating manual. Every participant reads the operating manual before the practical part. Where the two differ, the operating manual prevails.

WHY TRAINING IS MANDATORY

Hand-held laser welding puts the beam in a person’s hand. The MA1 reduces risks by design, but residual risks remain. They are controlled by the workplace, by organisation and by a trained operator. The following requirements define what this training has to cover.

Requirement Källa Covered in
Instructions for putting into service and use, including training of operators where necessary Regulation (EU) 2023/1230, Annex III, 1.7.4.2 Modules 4, 5; training path
Residual risks and protective measures to be taken by the user, including PPE Regulation (EU) 2023/1230, Annex III, 1.7.4.2 Modules 2, 3
Operating method in the event of accident or breakdown Regulation (EU) 2023/1230, Annex III, 1.7.4.2 Module 7
Adjustment and maintenance by the user, preventive maintenance Regulation (EU) 2023/1230, Annex III, 1.7.4.2 Module 6
Emission of non-ionising radiation and of hazardous substances (fumes) Regulation (EU) 2023/1230, Annex III, 1.7.4.2 Modules 1, 2, 3
Information for use on safe operation, PPE and emergency procedures for hand-held laser processing machines ISO 11553-2:2026 Modules 1–7
Operation only by qualified personnel who completed the THEO training; machine activation by authorization code MA1 operating manual, 2.4.2, 2.6.2, 4.2 Training path; record
Instruction of employees on hazards and protective measures by the employer National occupational safety law Training record
REGULATORY STATUS
Regulation (EU) 2023/1230 applies from 20 January 2027 and replaces the Machinery Directive 2006/42/EC.
ISO 11553-2:2026 (edition 2, published August 2026) replaces ISO 11553-2:2007. Its principle: safety is designed into the machine first; information for use and training cover what design cannot remove.

ROLES AND RESPONSIBILITIES

Role Responsibility
Employer Risk assessment, laser controlled area, PPE, appointment of a laser safety officer where required, instruction of employees, training records
Laser safety officer Supports the employer with the risk assessment, the safety measures and the monitoring of safe laser operation; works with the occupational safety specialist and the company physician
Operator Completes the training, works only as trained, wears PPE, checks the machine before use, reports defects
Trainer Runs the practical instruction, assesses competence, signs the training record
THEO / Maxphotonics Operating manual, THEO Academy, authorization code, spare parts and service

TRAINING PATH

Every operator completes all seven steps before welding unsupervised. Steps 1–4 run online at the THEO Academy (academy.theo.inc); the machine stays locked until the authorization code is entered.

Training path in seven steps

MODULES AT A GLANCE

Module Content Suggested time Method
1 Laser basics How the MA1 works, laser classes, eye and skin hazards, NOHD, reflections 30 min Online, classroom
2 Hazards and residual risks Radiation, fumes, fire, gas, electricity, noise; intended use and misuse 30 min Online, classroom
3 Protective measures MA1 safety functions, laser workplace, PPE, laser safety officer 45 min Classroom, walk-through
4 System and set-up Components, connections, gas, grounding, wire feeder, focus, activation 45 min Hands-on
5 Safe operation Daily check, start-up, parameters, torch handling, shut-down 60 min Hands-on
6 Care and wear parts Clean-first rule, protective window, nozzles, intervals 30 min Hands-on
7 Faults and emergencies Accident and fire, alarms, service contact 20 min Classroom, drill
8 Competence check Knowledge check and practical assessment, training record 30 min Assessment
Know the beam

MODULE 01 · LASER BASICS

KNOW THE BEAM

1080 NM. INVISIBLE. CLASS 4.

What the MA1 emits, why it is dangerous and how far the danger reaches.

HOW THE MA1 MAKES LIGHT

The MA1 is a fiber laser. Pump diodes feed light into an active fiber, which turns it into laser light. The armored fiber cable in the hose pack carries the beam to the torch. There, the optics collimate it, let it oscillate (wobble) and focus it onto the workpiece.

Beam path of the MA1

Laser light differs from the light of a lamp: it is coherent, spectrally pure and can be focused to an extreme power density. That is what makes it weld – and what makes it hazardous at a great distance.

INSIDE THE TORCH

Optical path inside the torch

LASER CLASSES

Lasers are classified by EN 60825-1 according to the accessible radiation. The higher the class, the higher the hazard and the more protective measures are required.

Class Hazard What it means
1 Safe under reasonably foreseeable conditions Glare and secondary accidents are possible
1M / 2M Safe for the naked eye Hazardous when viewed with optical instruments
2 Visible radiation, safe for short exposure (up to 0.25 s) Do not stare into the beam
3R Eye hazard Operating instruction and laser safety officer required
3B Eye hazard, skin hazard possible Operating instruction and laser safety officer required
4 Eye and skin hazard, also from diffuse reflection; fire hazard All MA1 models. Full protective measures and trained personnel

Unclassified laser devices without an identifiable laser class must not be used. The red pilot laser of the MA1 is a visible, low-power aiming beam; do not look into it either.

EYES AND SKIN

Wavelengths and the eye
Target Effect
Eye – retina Radiation between 400 and 1400 nm passes the cornea and is focused on the retina. The MA1 works at 1080 nm: invisible, no blink reflex, permanent damage within fractions of a second.
Eye – cornea and lens UV radiation and “blue light” from the welding plasma cause conjunctivitis and photochemical damage. Symptoms: blurred vision, burning, tears, a feeling of sand in the eyes.
Skin Above 45 °C tissue dies, above 150 °C it carbonises, above 300 °C it vaporises. Infrared and UV radiation cause burns and increase the risk of skin cancer.
Skin damage by temperature

HOW FAR THE DANGER REACHES

Med nominal ocular hazard distance (NOHD) is the distance within which the direct beam can damage the eye. For the MA1 series it is far longer than any workshop. The beam must therefore always be contained by the enclosure, walls or curtains of the laser controlled area.

Model Output power NOHD NHZ
MA1-35 ~800 W 118 m 22 m
MA1-45 ~1,200 W 144 m 27 m
MA1-65 ~1,500 W 178 m 34 m
MA1 ULTRA ~2,000 W 282 m 53 m

Source: MA1 operating manual, 11.2. NHZ = nominal hazard zone as stated in the operating manual.

REFLECTIONS

When the beam hits a surface, part of it is absorbed and turns into heat, part is transmitted and part is reflected. Shiny surfaces reflect like a mirror (specular reflection), matt surfaces scatter the beam in all directions (diffuse reflection). With a class 4 laser, both are hazardous.

Direct, specular and diffuse reflection
  • Aluminium and copper reflect a large part of the beam. Take special care.
  • Wrong parameters and a wrong torch angle increase reflections.
  • Know the expected reflection cone of every part and keep your body out of it.
INVISIBLE DOES NOT MEAN HARMLESS. LASER ENABLED MEANS THE BEAM IS THERE.
Know the risks

MODULE 02 · HAZARDS AND RESIDUAL RISKS

KNOW THE RISKS

BUILT SAFE. THESE RISKS REMAIN.

The MA1 is designed for safety. What design cannot remove, you control.

INTENDED USE

The MA1 laser welding system is a machine for the manual welding and soldering of steel, stainless steel, aluminium and similar materials. It is intended only for commercial use in an industrial environment, indoors. It is not intended for private use.

RESIDUAL RISKS AND YOUR PROTECTION

Hazard What can happen Protection
Laser radiation, direct Permanent eye damage, burns Laser controlled area, PPE, never point the torch at persons
Reflected and scattered radiation Eye and skin damage, also at an angle and at a distance Stay behind the torch, correct angle and parameters, PPE for everyone in the area
UV and blue light from the plasma Conjunctivitis, retinal damage, sunburn-like skin reactions Laser welding helmet, closed clothing; see a physician if symptoms occur
Welding fumes and gases Damage to lungs, heart, kidneys, nervous system; ozone and nitrogen oxides; shielding gas displaces air Extraction at the source, ventilation, safety data sheets, respiratory protection where needed, head out of the fumes
Fire and explosion Ignition of combustibles, solvents, containers No combustible material in the area, never weld on containers with unknown content, fire extinguisher at hand
Gas cylinders Explosion if damaged or heated Upright, secured, away from heat and sparks, suitable regulator
Electricity (200–240 V) Electric shock, burns Grounded supply, intact cables, never open the machine
Hot workpieces Burns Gloves; never set parts down where the laser can pass through
Noise, 85 dB(A) Hearing damage Hearing protection
Welding wire Eye injury when threading or moving the wire Never look into the liner, its outlet or the wire nozzle; safety goggles
Set-up and transport Tipping, rolling, tripping; 29–42 kg machine weight Two persons, level floor, brakes on, cables without loops
Overheating Ageing, loss of power, alarm stop 0–40 °C ambient, free air intake, 1 m clear around the machine

NEVER

These practices are foreseeable misuse. Each of them has caused accidents with hand-held lasers.

  • Operate the laser without the safety equipment specified by the manufacturer – or without PPE.
  • Manipulate, bypass or disable safety equipment such as the loop cable, key switch or interlock.
  • Point the torch at persons. The laser points at the work surface only.
  • Let untrained persons, children or persons who cannot operate the machine safely use it.
  • Weld in unventilated spaces, in explosive atmospheres or near combustible liquids and gases. The MA1 has no Ex protection.
  • Open, disassemble, modify or extend the machine or its electrical system.
  • Use the machine when damaged, especially the torch or safety equipment.
  • Exceed the operating parameters stipulated by the manufacturer.
  • Expose the machine to strong magnets, rapid temperature changes, humidity or wet environments.
A SAFETY FUNCTION IN YOUR WAY? STOP AND ASK. NEVER BYPASS IT.
Protect people

MODULE 03 · PROTECTIVE MEASURES

PROTECT PEOPLE

DESIGN FIRST. PPE LAST. NEVER PPE ONLY.

Machine, workplace, organisation, personal protection – in this order.

Protective measures follow a fixed order. Measures built into the machine and the workplace act without anyone having to remember them. PPE is the last line of defence – essential, but never the only one.

Hierarchy of protective measures

SAFETY FUNCTIONS OF THE MA1

Function What it does Operator check
Safety key switch Without the key in position 1, the machine powers on but the laser cannot be operated Key removed when not in use
Authorization code Machine works only after successful training and code entry Code valid; renew before expiry
Workpiece contact (loop cable) Laser emits only when the nozzle touches the workpiece and the trigger is pressed Clamp on the workpiece; Torch Switch status green on contact
Emergency stop Switches the laser off immediately and latches; release by turning Free access, “Emergency stop active!” clears after release
Interlock interface (EX-CTRL) Two-channel input for the door contact; laser cannot start while the circuit is open Door closed, Safety Lock status green
Fiber break detection Detects a broken fiber within 20 ms Never kink the hose pack; bend radius ≥ 200 mm
Indicators Torch LED and status signal show fault, standby and emission Know the states before welding
Monitoring Alarms for gas pressure, protective window temperature, grounding, overheating Read the Warning tab; act as in Module 7

WHEN DOES THE LASER EMIT?

The MA1 releases the beam only when every safety condition is met at the same time.

Conditions for laser emission

THE LASER WORKPLACE

The MA1 may only be operated in a laser welding cell or in an enclosure with interlocked safety devices. Setting up and maintaining this area is the employer’s responsibility; the operator checks it before every shift.

Laser workplace floor plan
  • Enclosure: laser protection booth, laser safety curtain or partition wall as per IEC 60825-4. Viewing panels only if rated for the laser.
  • Access: interlocked door connected to the EX-CTRL interface. The door contact switches the laser off on entry.
  • Signals: emission warning lights at every entrance; laser warning signs (class 4) outside at all access points, legible without exposure.
  • Air: fume extraction positioned directly at the welding zone; fresh air supply where needed.
  • Fire: fire extinguisher close by; work table free of debris, combustibles and reflective objects.
  • PPE: eyewear stored at the entrance, so nobody enters unprotected.
  • Light and space: no dark environments; sufficient room, traffic and escape routes; unauthorized persons stay out.

DANGER ZONE

During welding, the entire area in front of the torch is the danger zone. Only the operator works at the workpiece. Everyone else stays behind the torch and outside the reflection zone.

Danger zone, top view

PERSONAL PROTECTIVE EQUIPMENT

All PPE must match the output power and the wavelength range on the laser label of the machine. Persons in the immediate vicinity wear the same eye protection as the operator.

PPE for the operator
EYES AND FACE
Laser welding helmet (recommended) or laser safety goggles
EN 207:2017, full wavelength range
UNDER THE HELMET
Laser safety goggles as supplied: OD7+ D LB6 + IRM LB7 or OD8+ D LB6 + IRM LB8
HANDS
Laser- and heat-resistant gloves
EN 388, EN 12477, protection at 1070 nm
BODY
Welding jacket EN ISO 11611, long sleeves, collar closed
No synthetics, no reflective jewellery
Item Requirement (MA1 operating manual, 2.6.1)
Laser safety goggles Recommended up to 2,000 W CW and exposure < 1 m: OD9+ (1070–1075 nm) D LB6 + IR LB8 + M LB9 · OD8+ (1075–1080 nm) D LB6 + IRM LB8 · OD7+ (1080–1087 nm) D LB6 + IRM LB7
Laser welding helmet PPE Regulation (EU) 2016/425; EN ISO 16321-1:2022, EN ISO 16321-2:2021, EN 207:2017. Material 900–1100 D LB5 / LB7 R LB8; viewing window 900–1080 D LB7 IR LB8. Keep 500 mm distance along the line of sight, maximum safety angle 45°
Gloves EN 388:2016+A1, EN 12477:2001+A1:2005, suitable for use with EN ISO 11611 and EN ISO 11612 clothing
Clothing EN ISO 11611:2015 and EN ISO 13688; close-fitting, long, skin fully covered; long hair in a hair net
Further PPE Safety shoes, hearing protection; respiratory protection in small spaces or where required
CHECK THE EYEWEAR LABEL BEFORE EVERY USE: 1080 NM AND THE RIGHT PROTECTION LEVEL. DAMAGED EYEWEAR IS REPLACED.

LASER SAFETY OFFICER

Before class 3R, 3B or 4 lasers are operated, the employer appoints a laser safety officer where national law requires it or where the employer lacks the technical expertise. The laser safety officer is qualified by a training course, keeps that qualification up to date and supports the employer with the risk assessment, the safety measures and the monitoring of safe operation.

Set it up right

MODULE 04 · SYSTEM AND SET-UP

SET IT UP RIGHT

A SAFE WELD STARTS AT THE PLUG.

Components, connections, gas, wire, focus and activation.

SYSTEM OVERVIEW

MA1 system
MA1 front
MA1 rear
MA1 torch
Component Key elements
Lasersvets 7-inch touchscreen, status LED, emergency stop, safety key switch, safety loop interface, castors with brakes, cable reel
Rear panel Main switch, power input 200–240 V AC, EX-CTRL (door interlock, DB25), RS232 service interface, FEEDER connection, ground connection, shielding gas inlet
Hose pack and torch Armored fiber cable, gas tube, torch with laser trigger, wire feed switch, indicator LED, protective window and focus lens slots, scale tube, nozzle
T1 wire feeder On/off switch, manual feed and withdrawal buttons, continuous or pulsed feed at 2–100 mm/s, wire 0.8 / 1.0 / 1.2 / 1.6 mm

UNPACK AND PLACE

  • Inspect the packaging for transport damage; report damage to Maxphotonics.
  • Lift the laser welder out with two persons. Never lift it by the hose pack or cable.
  • Check the fiber cable for damage. Do not kink, crush or twist it.
  • Place the machine on a level surface and lock the castor brakes.
  • Keep the air intake underneath free and 1 m clear around the machine. Keep liquids and foreign objects away from the top.
  • Route cables so that they form no loops and no tripping hazards.

CONNECT

Switch the main switch off before connecting. Connect in this order:

Set-up view with connections a to g
Connection Obs
a Power cable Single-phase 200–240 V AC, grounded via protective earth; 16 A or 32 A depending on model
b Loop cable Front of the laser welder; workpiece clamp on the workpiece or table. Never connect the clamp to the torch – irreparable damage.
c EX-CTRL Door interlock switch; tighten both screws. Connection on site is the operator’s responsibility
d Shielding gas Gas hose (outside diameter 6 mm) to the push-in inlet on the rear
e Ground cable Ground nut of the housing to plant ground – protects against static discharge
f Wire feeder cable FEEDER on welder and wire feeder; red dot up
g Torch liner From wire feeder to the wire feed module on the torch

SHIELDING GAS

99.99 % Gas purity, argon or nitrogen
0.8–1.5 bar Inlet pressure
8–12 l/min Flow rate
≥ 8 l/min Pressure regulator with flow meter
Shielding gas supply

The shielding gas also cools the torch optics. Check the flow with the Gas manual button in Expert Mode. Choose the gas to suit the material:

Gas Strengths Limits
Argon (Ar) Inert, prevents oxidation; few pores in carbon steel; suits reactive metals Narrower weld profile
Nitrogen (N2) Low cost; very low pore formation in stainless steel; common for stainless steel and aluminium Can cause brittleness, especially in carbon steel
Ar/H2 (95/5 %) Best penetration in stainless steel Higher cost
Ar/O2 (2–4 %) Best penetration in carbon steel Carbon steel only

Source: THEO Application Workshop 2026, shielding gas case studies (wire feed, AISI 304 and S235).

PREPARE THE WIRE FEEDER

  • Spool: open the housing (mind your fingers), loosen the fastening nut, mount the spool so that the pin engages, tighten.
  • Rollers: U rollers for aluminium wire, V rollers for steel and stainless steel. The screws have a left-hand thread. Mount the rollers with type and diameter visible.
  • Thread the wire: levers down, guide the wire over both rollers into the liner connection until about 10 cm protrude, levers up.
  • Liner: lay it straight or in a wide radius. After rethreading, run the wire once completely through the liner.
Wire path through the feeder
WARNING – EYE INJURY
Never look into the liner connection, the liner outlet or the wire feeding nozzle while threading or moving the wire. Wear safety goggles.

PREPARE THE TORCH

  • Slide the wire feed module onto the scale tube and align the wire nozzle parallel to the welding nozzle, 2–5 mm apart.
  • The pilot laser must hit the centre of the extended wire.
  • Select the welding nozzle for the joint (fillet, lap, edge, inside or outside corner) and the wire nozzle for the wire diameter.
  • Set the focal plane on the scale tube: loosen the nut, set the value, tighten by hand.
Focal plane positions
Scale Focus position Typical use
0 to −15 Below the workpiece surface Thicker sheet
0 On the workpiece surface Reference position
0 to +15 Above the workpiece surface Thinner sheet

Rule of thumb from the Application Workshop: defocus negatively by about 2/3 of the material thickness and add the wire diameter; adjust to the joint.

ACTIVATE THE MACHINE

  1. Register the machine with the serial number from the delivery slip at the THEO Academy.
  2. Watch the training videos attentively, take notes, clarify open questions with your supervisor or THEO service.
  3. Complete the multiple-choice test and send it.
  4. Enter the authorization code received by e-mail under System Information > Authorization code.
Weld safely

MODULE 05 · SAFE OPERATION

WELD SAFELY

CHECK. START. WELD. STOP. EVERY TIME.

Daily check, start-up, parameters, torch handling and shut-down.

CHECK BEFORE EVERY SHIFT

# Check OK
01 Machine, torch and cables undamaged, nothing loose or missing; hose pack not kinked ☐
02 Protective window clean; red guide laser round and complete, without blind spots ☐
03 Welding nozzle and wire nozzle correct for the job and undamaged ☐
04 Loop cable intact, clamp on the workpiece ☐
05 Gas connected, cylinder upright and secured, flow 8–12 l/min ☐
06 Fume extraction running and positioned at the welding zone ☐
07 Laser area closed: curtains or walls complete, door interlock connected, warning light working, signs in place ☐
08 No combustible or reflective objects in the area; fire extinguisher accessible ☐
09 Emergency stop accessible ☐
10 PPE complete and matching the laser label; everyone in the area protected ☐

RED GUIDE LASER CHECK

Red guide laser OK and not OK

START-UP SEQUENCE

Start-up sequence in nine steps
WARNING
The laser emits only when the nozzle touches the workpiece and the trigger is held. Never try to “test” the beam in the air or on the hand.

SETTING PARAMETERS

Only trained personnel make entries on the display. Wrong settings increase reflections and can damage the system.

BASIC MODE

Basic Mode screen

Select material, thickness and joint type, choose whether to use the wire feeder, then enable the laser. Basic Mode uses verified factory presets and is the default after start-up. Fish scale pattern and, on the MA1-35, Mode D are available here.

EXPERT MODE

Expert Mode screen
Parameter Range / guidance
Laser power 0–100 % of machine maximum
Wobble width 0–4 mm; 2–3 mm recommended
Wobble frequency Up to 220 Hz at full wobble width; 40–80 Hz recommended for manual welding
Light mode CW (continuous), Pulse, Shooting (tack welding)
Gas on / off delay Pre-flow and post-flow time in ms
Ramp up / down Power ramp in ms; ramp up at least 100 ms
Wire feed Start low, about 10 mm/s; the wider the wobble, the slower the wire
Parameter sets Up to 32 custom sets under Process parameters > Customize

WOBBLE AND WIRE SPEED

Wobble frequency correct and wrong

REFERENCE VALUES – FILLET WELD WITHOUT WIRE

Material Thickness Effekt Wobble width Frequency Focus Gas flow
Carbon steel Q235B 1 / 1.5 / 2.5 mm 500 / 650 / 800 W 1–2 / 2 / 2.5 mm 60–80 / 60–80 / 50–70 Hz −1 to 1 / −1 to 1 / −2 to 1 8–10 l/min
Stainless SUS 304 1 / 2 / 2.5 mm 300 / 550 / 800 W 1–2 / 2 / 2.5 mm 40–70 Hz −1 to 1 / −1 to 1 / −2 to 1 8–10 l/min
Galvanized sheet 1 / 2 / 2.5 mm 300 / 400 / 500 W 1–2 / 2 / 2.5 mm 60–80 / 60–80 / 50–70 Hz −1 to 1 / −1 to 1 / −2 to 1 8–10 l/min
Aluminium Al6061 1 / 2 mm 600 / 800 W 1–2 / 2 mm 60–80 Hz −1 to 1 8–10 l/min

Source: MA1 operating manual, 11.4.1. Dragging position, nitrogen 99.99 %, welding speed about 10–20 mm/s. Reference values only – trial welds decide.

HANDLING THE TORCH

Torch angle do and don't
Do Don’t
Hold the torch head at 30°–70° to the workpiece. Best: handle parallel to the workpiece, about 70°. Hold the torch perpendicular: the beam reflects back into the optics and damages them.
Concentrate on guiding the torch. The wire carries the energy into the joint; there is little need to watch the melt pool. Hold the torch too flat: the beam reflects into the room and becomes uncontrolled.
Keep the torch below eye level and your head out of the fumes. Weld highly reflective material without extra care for multiple reflections.
Lift the torch to free the wire from the melt pool before releasing the trigger. Leave the machine unattended while it is ready to emit.
TORCH ANGLE IS A SAFETY SETTING: 30°–70° PROTECTS PEOPLE AND OPTICS.

STOP AND SWITCH OFF

Shut-down sequence
Keep it clean

MODULE 06 · CARE AND WEAR PARTS

KEEP IT CLEAN

THE BEST SERVICE IS THE ONE YOU DON’T NEED.

Most optical damage starts with dirt. Here is how to keep it out.

WHO DOES WHAT

Operator THEO service only
Cleaning of laser welder, torch and wire feeder; protective window (safety glass); welding and wire nozzles; wire feed rollers, spool and liner; visual inspections Opening the housing; focus lens, collimator, galvo; fiber and hose pack; electrical repairs; all faults not listed for the user. Disassembly without approval voids the warranty.

TORCH PARTS

Exploded view of the torch

FOUR RULES FOR OPTICS

Clean first. Open second. Clean the outside of the torch before opening any slot. External dirt becomes internal contamination. Never open a contaminated torch.
Keep the opening sideways. Never upward – dust falls in. Seal the focus tube with Kapton tape and close it immediately. Never leave optics exposed.
Contamination absorbs. A dirty window absorbs laser energy and creates a hot spot: burned coating, burned window, optical failure. Visibly clean does not mean optically safe – particles from 0.1 µm matter.
One way only. An optic that has been removed, contaminated or damaged is replaced, not cleaned and refitted.
Clean-first rules
Particle sizes

PREVENT BEFORE YOU REPAIR

  • Check the red guide laser before every weld: a blind spot, an irregular shape or a missing spot means a contaminated or damaged window.
  • Use the correct parameters and torch angle – they protect the optics and extend window life.
  • After a longer break, briefly purge the gas line to clear loose particles from the nozzle.
  • Keep grinding and dusty work away from the welding torch.
  • Check the Service Bulletins regularly.

CHANGE THE PROTECTIVE WINDOW

Protective window change in seven steps
  1. Switch off the main switch and disconnect the power supply.
  2. Clean the outside of the torch with a dry towel.
  3. Loosen the knurled screw and pull out the window compartment – opening sideways.
  4. Mask the shaft of the compartment with tape to protect the optics.
  5. Remove the sealing ring and tilt out the old window.
  6. Hold the new window against the light and check it is clean. Never touch it with bare fingers.
  7. Insert the new window and the sealing ring, remove the tape, insert the compartment and tighten the knurled screw.

Soot during welding or loss of power usually point to a contaminated window. If it fails again after a short time, contact THEO service.

INTERVALS

Maintenance intervals
When Task
Before every weld Check the red guide laser
Before every shift Visual inspection: fans run smoothly, gas hoses tight, wire feed module and insulation firm, loop cable intact; nozzle and protective window checked; wire feeder cable, buttons, brakes, liner, rollers
Weekly (recommended) Blow out the laser welder from the top with compressed air, maximum 2 bar, machine disconnected
Monthly Clean the wire feeder with a dry cloth and vacuum it; check rollers and pressure rollers for wear
At least every 2 months Clean ventilation channels and grille
At least every 3 months Remove the grille underneath (6 screws), vacuum and blow out the ventilation openings
As required Liner: blow out minor blockages, replace if heavily blocked. Torch: dry towel only, never compressed air

Regular inspection by THEO service is recommended for safe operation.

Act fast, act right

MODULE 07 · FAULTS AND EMERGENCIES

ACT FAST, ACT RIGHT

KNOW THE SEQUENCE BEFORE YOU NEED IT.

Emergencies, alarms, fault finding and where to get help.

EMERGENCIES

Emergency procedures

FAULTS YOU CAN FIX

Most stops are a safety function doing its job. Work through the chain before you call service.

Fault diagnosis: laser does not emit
Symptom / message Cause Action
Laser does not emit Safety key not in position 1 Insert the key, turn to position 1
Laser not enabled / pilot laser off on contact Loop cable not connected or clamp without contact Check loop cable, connection and clamp on the workpiece
Loss of power, soot Protective window contaminated Change the protective window (Module 6)
E-Stop Emergency stop pressed Remove the cause, turn the button to release
Interlock alarm Door open or interlock circuit not closed Close the door, check the EX-CTRL connection
Gas Shielding gas pressure too low Open the cylinder, check pressure and hoses
P-Lens Temp Protective window too hot Change the window; increase gas flow if necessary; call service if it recurs
Ground fault / Ground Connect Detection Protective earth not correctly connected Check connections; contact service
Torch Communicate No communication between laser and torch Check cables; contact service
Software expiring / code invalid Licence period reached or wrong code Re-enter the code; contact service for a new code
Overheating alarm Laser temperature too high; emission stops Switch off, improve ventilation, contact service
ANY OTHER MESSAGE IS FOR THEO SERVICE. NEVER OPEN THE MACHINE.

GETTING HELP

Open a service ticket with the serial number and a short description of the issue. For software updates, THEO service connects remotely via the RS232 interface.

THEO Europe c/o Maxphotonics GmbH · Dornierstraße 11 · 82205 Gilching · Germany
Telefon +49 (0) 8105 730 38 90
E-mail hello@theo.inc
Training THEO Academy · academy.theo.inc

TRANSPORT, STORAGE, DISPOSAL

Transport and store the machine protected against impact and humidity, ideally in the original packaging, within the permitted ambient conditions (storage −10 to 60 °C) and out of reach of unauthorized persons. Dispose of the machine and its components according to national regulations.

Prove it

MODULE 08 · COMPETENCE CHECK

PROVE IT

KNOWLEDGE CHECK. PRACTICAL TEST. SIGNATURE.

Ten questions, nine practical tasks, one record.

KNOWLEDGE CHECK

The trainer discusses every wrong answer before the practical assessment.

# Question Expected answer (trainer)
01 Why is the MA1 beam especially dangerous for the eyes? 1080 nm is invisible, triggers no blink reflex and is focused on the retina.
02 What does the NOHD tell you – and how large is it for your model? The distance within which the direct beam can damage the eye: 118–282 m depending on model.
03 Where do other persons stand during welding? Behind the torch, outside the reflection zone – or outside the laser area.
04 What must happen before the laser can emit? Key in position 1, door closed, laser enabled, nozzle in contact with the workpiece, trigger pressed.
05 Name three safety functions of the MA1. Any three: key switch, authorization code, workpiece contact, emergency stop, interlock, fiber break detection, monitoring.
06 Which torch angle is correct, and why? 30°–70°, best about 70°: no back-reflection into the optics, fewer reflections into the room.
07 What does an irregular red guide laser indicate? A contaminated or damaged protective window – change it before welding.
08 Where must the workpiece clamp never be connected? To the torch – irreparable damage.
09 Which eye protection is required? EN 207 goggles or helmet covering 1080 nm with the protection level on the laser label.
10 What do you do after an accident? Emergency stop, company accident procedures, physician immediately.

PRACTICAL ASSESSMENT

# Task – the participant … Passed
01 checks the laser area and the machine with the pre-shift checklist ☐
02 puts on and checks the PPE correctly ☐
03 connects loop cable, gas and ground correctly and sets the gas flow ☐
04 follows the start-up sequence without help ☐
05 selects suitable parameters for a given job ☐
06 welds with the correct torch angle and keeps others out of the danger zone ☐
07 stops and shuts down correctly and removes the key ☐
08 changes the protective window following the clean-first rule ☐
09 reacts correctly to an emergency stop and an interlock alarm ☐

REFERENCE

WORDS THAT MATTER

SHORT TERMS. CLEAR MEANING.

The terms used in this handbook and on the MA1.

Term Meaning
Authorization code Code sent by e-mail after the THEO Academy test. Unlocks the MA1 or extends its machine hours.
Basic Mode / Expert Mode Basic Mode: verified presets by material, thickness and joint. Expert Mode: every parameter set by hand.
Class 4 laser Highest laser class per EN 60825-1. Direct and diffuse radiation can damage eyes and skin and ignite materials.
Danger zone The whole area in front of the torch during welding. Only the operator works there.
EX-CTRL Interface on the rear panel for the two-channel door interlock and external control signals.
Interlock Safety circuit that switches the laser off when the door of the laser area opens.
Laser controlled area Enclosed area with interlocked access, warning lights and signs, where the MA1 may be operated.
LB / OD Protection level of laser eyewear (EN 207) / optical density. The higher the value, the stronger the protection at the stated wavelength.
Loop cable Cable from the laser welder to the workpiece clamp. The laser only emits when the nozzle touches the workpiece.
LSO Laser safety officer. Supports the employer with risk assessment, safety measures and monitoring of safe operation.
NOHD Nominal ocular hazard distance: the distance within which the direct beam can damage the eye (MA1: 118–282 m).
NHZ Nominal hazard zone as stated in the MA1 operating manual (MA1: 22–53 m).
PPE Personal protective equipment: laser helmet or goggles, gloves, welding jacket, safety shoes, hearing protection.
Protective window Coated safety glass at the torch exit. Protects the focus lens; a wear part changed by the operator.
Red guide laser Visible pilot beam showing the welding spot. Its shape shows whether the protective window is clean.
Wobble Oscillation of the beam across the seam, set by width (mm) and frequency (Hz).

RECORD

TRAINING RECORD

SIGNED. FILED. REFRESHED EVERY YEAR.

Keep this record with the employer’s safety documentation. Repeat the instruction at least annually and after any change.

Participant (name)
Company / site
Machine model and serial number
THEO Academy certificate (date)
Authorization code entered (date)
Trainer (name, organisation)
Date and location of practical training
Module Completed Module Completed
1 Laser basics ☐ 5 Safe operation ☐
2 Hazards and residual risks ☐ 6 Care and wear parts ☐
3 Protective measures ☐ 7 Faults and emergencies ☐
4 System and set-up ☐ 8 Competence check passed ☐

By signing, the participant confirms having received and understood the instruction and the operating manual. The trainer confirms the competence check. The employer confirms authorization to operate the MA1.

 
 
 
 
 
 
Date, signature participant Date, signature trainer Date, signature employer / LSO
Next refresher due

Related documents: Bruksanvisning för THEO MA1 · THEO MA1 Series | Driftparametrar · Get Ready for Delivery