Opens in a new tab
Laser safety

Protect your lungs

Laser welding and laser cleaning create fumes. How to keep them out of your lungs, and the equipment THEO recommends.
See the recommendations

What you weld, you shouldn't breathe.

Welding fumes are fine particles and gases. They come from the base metal, the filler wire, the shielding gas, and from whatever is on the surface: paint, coatings, residue.

The UK’s Health and Safety Executive (HSE) says it plainly: all welding fume can cause lung cancer, and there is no known level of safe exposure. That includes mild steel. The International Agency for Research on Cancer classifies welding fume as carcinogenic to humans.

What is in the fume depends on the metal. Mild steel fume contains manganese. Stainless steel fume contains hexavalent chromium and nickel, which can cause occupational asthma. Fume from galvanised metal is linked to metal fume fever, with flu-like symptoms.

HSE: health risks from welding

Laser cleaning makes fumes too.

A cleaning laser removes corrosion layers, paint and coatings by turning them into particles, fumes and vapors. What was on the surface is then in the air, and old coatings can contain lead, chromates or zinc.

Germany’s statutory accident insurance (DGUV) names two main hazards of laser cleaning: the laser radiation and the hazardous substances the process creates. Its guidance asks for an efficient extraction system that captures them as close to the point of origin as possible.

The MA1 manual names what such fumes can affect: lungs, heart, kidneys and the central nervous system. So the same rule applies to cleaning as to welding: capture the fume where it is made.

DGUV: cleaning and stripping with laser radiation (FBHM-139, in German)

Fume extraction hood pulling smoke away from a laser welding workstation

Three layers of protection.

1. Extract at the source

HSE asks for engineering controls for all indoor welding, typically local exhaust ventilation: a hood or nozzle that captures the fume where it is made, and a filter unit behind it.

2. Add a respirator

Where extraction alone cannot control the exposure, HSE asks for respiratory protection as well. A PAPR, a powered air-purifying respirator, blows filtered air into the helmet or mask.

3. Look after the room

THEO's manuals ask for a fume extraction system that removes fumes, vapors and particles from the work area, fresh air in small spaces, and regular checks of the air quality. In a closed welding cell, extraction is mandatory.

Recommended by THEO

Fume extractors.

For fume extraction THEO recommends Kemper and Filtrabox. The details below are the makers' own.

Kemper MaxiFil Clean mobile extraction unit

Kemper MaxiFil Clean

Processes MIG/MAG, MMA, laser

Use Continuous

Kemper FilterMaster XL mobile extraction unit

Kemper FilterMaster XL

Processes Welding and laser

Filter class W3, IFA tested

Filtrabox Weld-RX laser fume extractor

Filtrabox Weld-RX

Made for Handheld laser welding

Filter H14 HEPA with F9 prefilter

Duct 8 inch

More from the makers: kemper.eu and filtrabox.com.

Recommended by THEO

Powered air respirators (PAPR).

For PAPR THEO recommends optrel, and the Laservision PAPR unit, which fits THEO's VIZ laser welding helmets.

optrel e3000X PAPR blower unit

optrel e3000X

Class TH3

Airflow Up to 240 l/min, three levels

Battery Up to 18 h

optrel swiss air PAPR with half mask

optrel swiss air

Class TH3 with the cloth half mask

Airflow Stepless control

Laservision PAPR unit with ventilated half mask
Swiss Air PAPR Mask

Laservision PAPR for Panoramaxx laser welding helmets

Filter unit TH3

Battery 14 hours

Head harness XS to XL

  • Fits THEO’s VIZ laser welding helmets
  • Flame-retardant ventilated half mask
  • Automatic airflow calibration
  • Control panel for filter and battery status

Why a PAPR matters for laser welding, in optrel’s words: The Invisible Threat: Why PAPR is Essential for Laser Welding Safety.

Frequently asked questions

Fume extraction and PAPR

Is a respirator enough on its own?

No. A respirator protects the person wearing it. HSE asks for extraction first and respiratory protection where extraction alone is not enough, and THEO’s manuals require a fume extraction system. In a closed welding cell, extraction is mandatory.

Do the people around me need protection too?

Yes. Everyone in the immediate vicinity wears the same protective equipment as the welder, and they breathe the room’s air: another reason for extraction.

Does laser cleaning need extraction?

Yes. The laser turns corrosion layers, paint and coatings into particles, fumes and vapors. DGUV’s guidance on laser cleaning asks for extraction that captures them as close to the point of origin as possible.

Is a welding fume extractor enough for laser fume?

Only if its filter is rated for fine particles. Laser welding and laser cleaning produce very fine particles, so check the filter with your THEO Partner before you rely on an existing unit. For fume extraction THEO recommends Kemper and Filtrabox: see fume extractors.

Helmets and glasses

Glasses on. Helmet on.

THEO recommends both, for everyone in the laser area.

Two THEO laser welding helmets

Laser welding safety

Safety. Matters.

What a laser-safe workplace needs.

THEO laser welding helmet

Not sure what your shop needs?

Tell us what you weld or clean, and where. We'll point you to the right setup.

Your request

It takes about a minute. Fields with * are required.

We reply within one business day.