{"id":16741,"date":"2026-10-15T13:04:05","date_gmt":"2026-10-15T13:04:05","guid":{"rendered":"https:\/\/go.theo.inc\/manuals\/ma1-gas-plumbing-guide-us\/"},"modified":"2026-10-17T17:57:29","modified_gmt":"2026-10-17T17:57:29","password":"","slug":"ma1-gas-plumbing-guide-us","status":"publish","type":"docs","link":"https:\/\/go.theo.inc\/ko\/knowledge-base\/ma1-gas-plumbing-guide-us\/","title":{"rendered":"THEO MA1 \uc2dc\ub9ac\uc988 \ud29c\ud1a0\ub9ac\uc5bc (US) | \uac00\uc2a4 \ubc30\uad00 \uac00\uc774\ub4dc"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Like electricity, plumbing the MA1 to your gas source is up to you. Our applications team has tested a lot of hardware, and the parts below are what works most consistently in US shops.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The MA1 has a <strong>6 mm push-in gas inlet<\/strong>. It ships with a 10 mm gas hose and one 10 mm \u2192 6 mm adapter. With the setups below, set the flow to <strong>12\u201315 l\/min (25\u201332 cfh)<\/strong>. Everything else about gas is in <a href=\"https:\/\/go.theo.inc\/ko\/manuals\/ma1-get-ready-for-delivery\/#shielding-gas\">Get Ready for Delivery<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Connecting a standard regulator<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"max-width:315px\"><img decoding=\"async\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2026\/10\/theo-ma1-gas-plumbing-regulators.jpg\" alt=\"Five gas regulators with flow meters, each fitted with a flare coupling and a push-to-connect fitting for the MA1\" width=\"315\" height=\"306\" class=\"wp-image-16739\" srcset=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2026\/10\/theo-ma1-gas-plumbing-regulators.jpg 315w, https:\/\/go.theo.inc\/wp-content\/uploads\/2026\/10\/theo-ma1-gas-plumbing-regulators-12x12.jpg 12w\" sizes=\"(max-width: 315px) 100vw, 315px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">These five regulators were all plumbed to the MA1&#8217;s 6 mm inlet with two parts:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li><strong>Flare end coupling:<\/strong> <a href=\"https:\/\/www.amazon.com\/dp\/B0786Z38GJ\" rel=\"nofollow\" target=\"_blank\">Anderson Metals 754046-0604, 3\/8\u2033 flare \u00d7 1\/4\u2033 FPT<\/a><\/li>\n\n\n<li><strong>10 mm tube to 1\/4\u2033 NPT<\/strong> (bottom left in the photo): <a href=\"https:\/\/www.amazon.com\/dp\/B08S3HQ85J\" rel=\"nofollow\" target=\"_blank\">TAILONZ straight push-to-connect fitting, 10 mm tube OD \u00d7 1\/4\u2033 MNPT<\/a><\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Then run the supplied 10 mm hose from that fitting, through the 10 mm \u2192 6 mm adapter, to the MA1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>&#8220;Nearly every standard regulator I&#8217;ve encountered since starting with THEO has been threaded for this coupling, either within the regulator body itself or with adaptors included with the regulator, as seen in the first image.&#8221;<\/em><br><strong>Harrison Shoup<\/strong>, THEO Applications Manager<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Without the reducer<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"max-width:160px\"><img decoding=\"async\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2026\/10\/theo-ma1-gas-plumbing-elbow-fitting.jpg\" alt=\"A 6 mm push-to-connect elbow fitting next to a straight fitting, both with 1\/4 inch NPT threads\" width=\"160\" height=\"241\" class=\"wp-image-16740\" srcset=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2026\/10\/theo-ma1-gas-plumbing-elbow-fitting.jpg 99w, https:\/\/go.theo.inc\/wp-content\/uploads\/2026\/10\/theo-ma1-gas-plumbing-elbow-fitting-8x12.jpg 8w\" sizes=\"(max-width: 160px) 100vw, 160px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">To skip the 10 mm \u2192 6 mm reducer, thread a <a href=\"https:\/\/www.amazon.com\/dp\/B08XGWXRKH\" rel=\"nofollow\" target=\"_blank\">TAILONZ PL6-N2 elbow (6 mm tube OD \u00d7 1\/4\u2033 NPT, 90\u00b0)<\/a> straight into the flare coupling, then plumb it to the regulator and run 6 mm tube to the MA1.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Connecting a panel flowmeter<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"max-width:285px\"><img decoding=\"async\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2026\/10\/theo-ma1-gas-plumbing-panel-flowmeter.jpg\" alt=\"An acrylic panel flowmeter with two push-to-connect fittings, short 10 mm tubes and reducers to 6 mm tubing\" width=\"285\" height=\"482\" class=\"wp-image-16752\" srcset=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2026\/10\/theo-ma1-gas-plumbing-panel-flowmeter.jpg 285w, https:\/\/go.theo.inc\/wp-content\/uploads\/2026\/10\/theo-ma1-gas-plumbing-panel-flowmeter-7x12.jpg 7w\" sizes=\"(max-width: 285px) 100vw, 285px\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Thread two <a href=\"https:\/\/www.amazon.com\/dp\/B08S3HQ85J\" rel=\"nofollow\" target=\"_blank\">TAILONZ straight push-to-connect fittings (10 mm tube OD \u00d7 1\/4\u2033 NPT)<\/a> into the female ports of an <a href=\"https:\/\/www.amazon.com\/dp\/B07Z4ZG1LJ\" rel=\"nofollow\" target=\"_blank\">LZM-6T acrylic panel flowmeter<\/a>.<\/li>\n\n\n<li>From each fitting, run about 1.5\u2033 of 10 mm tube to a <a href=\"https:\/\/www.amazon.com\/dp\/B07C7H9QFH\" rel=\"nofollow\" target=\"_blank\">push-to-connect reducer union, 10 mm \u00d7 6 mm OD<\/a>.<\/li>\n\n\n<li>Connect 6 mm tube in from the gas source and out to the purge.<\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The LZM-6T reads only <strong>1\u201310 l\/min (2\u201321 cfh)<\/strong>. That is below the 12\u201315 l\/min (25\u201332 cfh) the MA1 needs. For the MA1, use a panel flowmeter that reads to at least 15 l\/min (32 cfh).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">One gas source for the MA1 and a purge line<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To split one gas source between the MA1 and a purge line, use a <a href=\"https:\/\/www.amazon.com\/dp\/B086MPQS63\" rel=\"nofollow\" target=\"_blank\">TAILONZ PE-6 tee (3-way, 6 mm tube OD, push-to-connect)<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Before the first weld:<\/strong> chain the cylinder upright, leak-check every connection and set the flow (12\u201315 l\/min \/ 25\u201332 cfh) with <em>Gas Manual<\/em> in Expert Mode.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Product links go to Amazon US listings that our team has used. Listings change, so check the size and thread before you order.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Related: <a href=\"https:\/\/go.theo.inc\/ko\/manuals\/ma1-tutorial-gas-regulators-us\/\">THEO MA1 Series \ud29c\ud1a0\ub9ac\uc5bc | \uac00\uc2a4 \ub808\uade4\ub808\uc774\ud130<\/a> (video) \u00b7 <a href=\"https:\/\/go.theo.inc\/ko\/manuals\/ma1-get-ready-for-delivery\/\">Get Ready for Delivery<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Like electricity, plumbing the MA1 to your gas source is up to you. Our applications team has tested a lot of hardware, and the parts below are what works most consistently in US shops. The MA1 has a 6 mm push-in gas inlet. It ships with a 10 mm gas hose and one 10 mm [&hellip;]<\/p>\n","protected":false},"author":958,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"doc_category":[127,396],"doc_tag":[],"class_list":["post-16741","docs","type-docs","status-publish","hentry","doc_category-theo-ma1-knowledge","doc_category-tutorials"],"acf":[],"year_month":"2026-11","word_count":391,"total_views":"51","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"claude_restapi","author_nicename":"claude_restapi","author_url":"https:\/\/go.theo.inc\/ko\/blog\/author\/908fb14138ca16e880831b2922186cd9\/"},"doc_category_info":[{"term_name":"THEO Knowledge Base","term_url":"https:\/\/go.theo.inc\/ko\/manuals-category\/theo-ma1-knowledge\/"},{"term_name":"Tutorials","term_url":"https:\/\/go.theo.inc\/ko\/manuals-category\/tutorials\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/go.theo.inc\/ko\/wp-json\/wp\/v2\/docs\/16741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/go.theo.inc\/ko\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/go.theo.inc\/ko\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/go.theo.inc\/ko\/wp-json\/wp\/v2\/users\/958"}],"replies":[{"embeddable":true,"href":"https:\/\/go.theo.inc\/ko\/wp-json\/wp\/v2\/comments?post=16741"}],"version-history":[{"count":0,"href":"https:\/\/go.theo.inc\/ko\/wp-json\/wp\/v2\/docs\/16741\/revisions"}],"wp:attachment":[{"href":"https:\/\/go.theo.inc\/ko\/wp-json\/wp\/v2\/media?parent=16741"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/go.theo.inc\/ko\/wp-json\/wp\/v2\/doc_category?post=16741"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/go.theo.inc\/ko\/wp-json\/wp\/v2\/doc_tag?post=16741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}