{"id":16722,"date":"2026-10-08T11:48:19","date_gmt":"2026-10-08T11:48:19","guid":{"rendered":"https:\/\/go.theo.inc\/manuals\/ma1-get-ready-for-delivery\/"},"modified":"2026-11-13T16:28:32","modified_gmt":"2026-11-13T16:28:32","password":"","slug":"ma1-get-ready-for-delivery","status":"publish","type":"docs","link":"https:\/\/go.theo.inc\/hu\/knowledge-base\/ma1-get-ready-for-delivery\/","title":{"rendered":"K\u00e9sz\u00fclj\u00f6n fel a sz\u00e1ll\u00edt\u00e1sra \u2014 THEO MA1 Series"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Your THEO MA1 is on its way. Four steps get you from delivery to your first weld: prepare your space, unbox, set up, weld. Each step has two or three things to check, with a link if you want the detail. Starting a 7-day trial? This is all you need.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u26a0\ufe0f Safety first.<\/strong> The MA1 is a <strong>Class 4 laser product<\/strong>. Nobody welds without a laser-safe work area, a working door interlock and laser safety goggles (OD7+ \/ OD8+, included in the box) for everyone inside the area. The MA1 will not fire while its interlock circuit is open.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"before-delivery\">\u2705 1. Before delivery<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>\u2610 <strong>A laser-safe work area:<\/strong> curtains or an enclosure, warning signs at every entry and a door interlock switch. <a href=\"#laser-safety\">What a laser-safe area needs<\/a><\/li>\n\n\n<li>\u2610 <strong>Teljes\u00edtm\u00e9ny:<\/strong> a dedicated 200\u2013240 V single-phase circuit, not shared with any other machine. <strong>The MA1 ships without a plug<\/strong>, so your electrician fits one before delivery. <a href=\"#power\">Plug and circuit by country<\/a><\/li>\n\n\n<li>\u2610 <strong>Shielding gas:<\/strong> an argon or nitrogen cylinder (99.996 %) with a regulator and flow meter that reaches 15 l\/min, plus fume extraction. <a href=\"#shielding-gas\">Gas requirements<\/a><\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"unboxing\">\ud83d\udce6 2. Unboxing<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>\u2610 Check the crate for transport damage before you sign, and photograph anything suspicious.<\/li>\n\n\n<li>\u2610 Unpack with two people (28\u201342 kg depending on model). Lift by the housing, never by the cable-hose assembly.<\/li>\n\n\n<li>\u2610 Check the contents against <a href=\"#in-the-box\">what is in the box<\/a>. Watch the unboxing video: <a href=\"https:\/\/go.theo.inc\/hu\/manuals\/ma1-tutorial-unboxing-and-setup-eu\/\">Eur\u00f3pa<\/a> \u00b7 <a href=\"https:\/\/go.theo.inc\/hu\/manuals\/ma1-tutorial-unboxing-and-setup-us\/\">USA<\/a><\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"setup\">\ud83d\udd27 3. Setup<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>\u2610 Place the machine in a dry, clean spot with 1 m of free space all around. Keep the air inlet underneath and the outlet on top clear.<\/li>\n\n\n<li>\u2610 Connect in this order: ground cable \u2192 loop cable \u2192 door interlock (EX-CTRL) \u2192 gas \u2192 power. <a href=\"https:\/\/go.theo.inc\/hu\/manuals\/ma1-operator-manual\/\">Step by step in the Operator Manual (\u00a74.3.1)<\/a><\/li>\n\n\n<li>\u2610 Open the gas, set <strong>12\u201315 l\/min<\/strong> with <em>Gas Manual<\/em> in Expert Mode and leak-check every connection.<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"first-weld\">\u26a1 4. First weld<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>\u2610 Download the free <a href=\"https:\/\/go.theo.inc\/toolbox-app\/\">THEO Toolbox alkalmaz\u00e1s<\/a>.<\/li>\n\n\n<li>\u2610 Find the pWPS for your material and thickness and set the parameters it gives you.<\/li>\n\n\n<li>\u2610 Train every operator before they weld on their own: <a href=\"https:\/\/go.theo.inc\/hu\/manuals\/ma1-operator-handbook\/\">THEO MA1 kezel\u0151i k\u00e9zik\u00f6nyv<\/a>.<\/li>\n\n\n<li>\u2610 Goggles on, door closed, then start on a scrap piece. Stuck? Ask THEO AI or a THEO expert in the app.<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udccb The details<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Everything below backs up the four steps. Send the power section to your electrician and the laser safety section to whoever runs safety in your shop.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"laser-safety\">\ud83d\udee1\ufe0f Laser safety area<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Before the first weld, not after, you need a laser-controlled area: an enclosure or laser safety curtains, warning signs at every entry point, a <strong>door interlock<\/strong> wired to the machine (see <a href=\"#interlock\">door interlock and emergency stop<\/a>) and laser-rated PPE for everyone inside.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The full guide, including what a Laser Safety Officer needs: <strong><a href=\"https:\/\/go.theo.inc\/hu\/blog\/laser-welding-safety-setup-a-laser-welding-work-environment\/\">Biztons\u00e1gos l\u00e9zerhegeszt\u00e9s: \u00edgy alak\u00edtsa ki a munkak\u00f6rnyezetet<\/a><\/strong>. The beam data your LSO will ask for is in <a href=\"https:\/\/go.theo.inc\/hu\/manuals\/theo-ma1-series-operating-parameters\/\">THEO MA1 Series | \u00dczemi param\u00e9terek<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Laser safety goggles (OD7+ \/ OD8+) are in the box. We recommend a laser-rated welding helmet (THEO VIZ-R) and gloves as well.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"power\">\ud83d\udd0c Power: one machine, one circuit<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The MA1 needs its own dedicated circuit. It cannot share a circuit with your TIG or MIG welder, a compressor or a fume extractor.<\/strong> The MA1-65 and Ultra draw up to 6 kW, so a shared circuit trips the breaker mid-weld or starves the laser. Have your electrician run a dedicated line to where the machine will stand.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">All MA1 models run on <strong>200\u2013240 V AC, single-phase<\/strong>. No three-phase power is needed.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Input power (100 % laser output)<\/th>\n<th>\ud83c\uddea\ud83c\uddfa Planning current at 230 V<\/th>\n<th>\ud83c\uddfa\ud83c\uddf8 Planning current at 208\u2013240 V<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>MA1-35<\/td>\n<td>3,000 W<\/td>\n<td>~13 A<\/td>\n<td>~13\u201315 A<\/td>\n<\/tr>\n<tr>\n<td>MA1-45<\/td>\n<td>4,800 W<\/td>\n<td>~21 A<\/td>\n<td>~20\u201323 A<\/td>\n<\/tr>\n<tr>\n<td>MA1-65<\/td>\n<td>6,000 W<\/td>\n<td>~26 A<\/td>\n<td>~25\u201329 A<\/td>\n<\/tr>\n<tr>\n<td>MA1 Ultra<\/td>\n<td>6,000 W<\/td>\n<td>~26 A<\/td>\n<td>~25\u201329 A<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Currents are calculated from rated input power (P \u00f7 V). They are planning values for your electrician.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The MA1 is delivered with a power cable but without a plug.<\/strong> Plug standards differ by country and by the circuit in your shop, so a licensed electrician fits the plug on site. Plan this before delivery: it is the most common reason a new MA1 sits idle on day one.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83c\uddea\ud83c\uddfa EU \u00b7 \ud83c\uddec\ud83c\udde7 UK \u00b7 \ud83c\udde6\ud83c\uddfa Australia: what to tell your electrician<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li><strong>MA1-45, MA1-65, MA1 Ultra:<\/strong> a <strong>32 A single-phase CEE plug (IEC 60309, blue, 230 V, 2P+E)<\/strong> on a <strong>dedicated 32 A circuit<\/strong>. A standard 16 A Schuko socket is <strong>not<\/strong> enough.<\/li>\n\n\n<li><strong>MA1-35:<\/strong> ~13 A, so a <strong>16 A Schuko (Type F) or 16 A CEE blue plug<\/strong> on a dedicated 16 A circuit.<\/li>\n\n\n<li>UK: 32 A IEC 60309 blue. A 13 A BS 1363 plug is not suitable for any model. Australia: 32 A single-phase industrial plug (AS\/NZS 3123), or 15\/20 A for the MA1-35.<\/li>\n\n\n<li>Breaker type (B\/C) per your electrician; a 30 mA RCD is typical in workshops.<\/li>\n\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83c\uddfa\ud83c\uddf8 USA \u00b7 \ud83c\udde8\ud83c\udde6 Canada: what to tell your electrician<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li><strong>MA1-45, MA1-65, MA1 Ultra:<\/strong> a <strong>dedicated 208\u2013240 V, single-phase, 30 A circuit as a minimum<\/strong>. Typical welder receptacles: <strong>NEMA L6-30<\/strong> (30 A twist-lock) or <strong>NEMA 6-50<\/strong> (50 A straight-blade &#8220;welder outlet&#8221;), the most common one in welding shops. A 50 A circuit is fine; the MA1 only draws what it needs.<\/li>\n\n\n<li><strong>MA1-35:<\/strong> ~13\u201315 A, so a <strong>NEMA 6-20<\/strong> on a dedicated 20 A circuit works; L6-30 and 6-50 work too.<\/li>\n\n\n<li>Canada: same receptacles, sized per CEC by your electrician.<\/li>\n\n\n<li>The MA1 is a <strong>two-wire-plus-ground<\/strong> load (L1, L2, PE). It has no neutral, so a 4-wire NEMA 14-xx receptacle is not required.<\/li>\n\n\n<li>Video walkthrough: <a href=\"https:\/\/go.theo.inc\/hu\/manuals\/ma1-tutorial-power-connection-us\/\">THEO MA1 Series oktat\u00f3anyag (US) | Elektromos csatlakoztat\u00e1s<\/a><\/li>\n\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u26d4 Do not<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Do not run the MA1 from an extension cord or a multi-outlet strip.<\/li>\n\n\n<li>Do not share the circuit with a TIG\/MIG welder, compressor, fume extractor or anything else.<\/li>\n\n\n<li>Do not use a generator or inverter unless it is rated for the full input power with a clean sine wave.<\/li>\n\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Grounding<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The MA1 ships with a <strong>ground cable (5 m or 10 m)<\/strong> for electrostatic grounding. Have a <strong>plant\/earth ground point<\/strong> (ground bar, bonded steel, earthing stud) within reach of the machine. This is separate from the <strong>loop cable (3 m)<\/strong> with the workpiece clamp, which closes the safety circuit to the workpiece.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"shielding-gas\">\ud83e\uddea Shielding gas<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table>\n<thead>\n<tr>\n<th>Item<\/th>\n<th>Requirement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Gas<\/td>\n<td>Argon (steel, stainless, general) or nitrogen (stainless steel, aluminium)<\/td>\n<\/tr>\n<tr>\n<td>Purity<\/td>\n<td>99.996 % minimum<\/td>\n<\/tr>\n<tr>\n<td>Inlet pressure at the machine<\/td>\n<td>0.8\u20131.5 bar (12\u201322 psi)<\/td>\n<\/tr>\n<tr>\n<td>Flow rate<\/td>\n<td><strong>12\u201315 l\/min (25\u201332 cfh)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Regulator<\/td>\n<td>Pressure regulator with flow meter that reaches at least 15 l\/min (32 cfh)<\/td>\n<\/tr>\n<tr>\n<td>Gas hose<\/td>\n<td>Included: a 10 mm gas hose with an adapter to the machine&#8217;s 6 mm push-in inlet<\/td>\n<\/tr>\n<tr>\n<td>How long a cylinder lasts<\/td>\n<td>About 11\u201314 hours of welding from a 50 l \/ 200 bar cylinder; about 8\u201310 hours from a 250 cf cylinder<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The torch is gas-cooled: the shielding gas also cools the fibre connector and optics. No gas, or too little pressure, triggers a gas-pressure fault, so set the regulator before the first weld.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Chain the cylinder upright to a wall or cart before you connect it. Keep it away from heat, sparks and the weld zone.<\/li>\n\n\n<li>Leak-check all connections before the first weld.<\/li>\n\n\n<li>Already running TIG? Keep your cylinder, supplier and regulator.<\/li>\n\n\n<li>In the US: <a href=\"https:\/\/go.theo.inc\/hu\/manuals\/ma1-gas-plumbing-guide-us\/\">Gas Plumbing Guide (US)<\/a> with the fittings our applications team uses, and the <a href=\"https:\/\/go.theo.inc\/hu\/manuals\/ma1-tutorial-gas-regulators-us\/\">gas regulators video<\/a>.<\/li>\n\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"interlock\">\ud83d\udeaa Door interlock and emergency stop<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The MA1 will not fire unless its interlock circuit is closed. The DB25 &#8220;EX-CTRL&#8221; safety interface on the rear panel has two independent interlock channels (EXLOCK1, EXLOCK2). Both must be closed by potential-free (dry) contacts, typically a door contact switch on your laser enclosure or curtain entrance. <strong>Never apply external voltage to these pins.<\/strong> Installing a suitable door switch and making sure it works reliably is the operator&#8217;s responsibility (manual \u00a72.6.2.5, \u00a74.3.1).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">What you need on site:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>A <strong>two-channel safety door switch<\/strong> (positively guided or mechanically coded, for example a safety-rated door contact with two NC contacts) for each access point to the laser area<\/li>\n\n\n<li>An <strong>emergency stop button<\/strong> if your laser-area design needs one outside the machine (EMG1\/EMG2 inputs, 24 V signal)<\/li>\n\n\n<li>Optional: an external warning lamp driven from the Fault relay output (pins 1\/14)<\/li>\n\n\n<li>A <strong>DB25 male connector<\/strong> or a pre-made interlock cable from the door switch to the machine<\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pinout, wiring diagram and step-by-step connection: <a href=\"https:\/\/go.theo.inc\/hu\/manuals\/ma1-operator-manual\/\">THEO MA1 Series Operator Manual<\/a> (\u00a73.5.1 Safety interface, \u00a74.3.1 Connecting the laser welder). Mount the door switch and pull the cable before delivery; connecting it on the day takes five minutes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"fume-extraction\">\ud83c\udf2c\ufe0f Fume extraction and placement<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Laser welding produces fume and dust. Have an extraction unit ready; in small rooms add a fresh-air supply.<\/li>\n\n\n<li>The laser is air-cooled, so no water chiller is needed. Keep the air inlet underneath and the outlet on top unobstructed.<\/li>\n\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"in-the-box\">\ud83d\udce6 What is in the box<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Laser welder with torch and power cable (no plug)<\/li>\n\n\n<li>Wire feeder (packaged separately) with stainless torch liner and feed rollers<\/li>\n\n\n<li>Ground cable (5 m or 10 m); loop cable (3 m) with workpiece clamp<\/li>\n\n\n<li>10 mm gas hose with an adapter to 6 mm<\/li>\n\n\n<li>Laser safety goggles (OD7+ \/ OD8+)<\/li>\n\n\n<li>Welding nozzles (1, 3, A, B, flat; 2 each); wire-feed nozzles 0.8 \/ 1.0 \/ 1.2 \/ 1.6 mm<\/li>\n\n\n<li>Protective glasses \u00f820 \u00d7 3 (5 pcs); cleaning sticks<\/li>\n\n\n<li>Operating manual, safety instructions, safety labels<\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Not in the box, you provide:<\/strong> plug, gas cylinder, regulator with flow meter, welding wire, helmet, fume extraction, laser safety enclosure or curtains, door interlock switch.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"technical-data\">M\u0171szaki adatok<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table>\n<thead>\n<tr>\n<th><\/th>\n<th>MA1-35<\/th>\n<th>MA1-45<\/th>\n<th>MA1-65<\/th>\n<th>MA1 Ultra<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Supply<\/td>\n<td colspan=\"4\">200\u2013240 V AC, single-phase<\/td>\n<\/tr>\n<tr>\n<td>Input power (100 %)<\/td>\n<td>3,000 W<\/td>\n<td>4,800 W<\/td>\n<td>6,000 W<\/td>\n<td>6,000 W<\/td>\n<\/tr>\n<tr>\n<td>Laser output<\/td>\n<td>Up to 800W<\/td>\n<td>Up to 1200W<\/td>\n<td>Up to 1500W<\/td>\n<td>Up to 2000W<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>29 \u00b1 3 kg<\/td>\n<td>38 \u00b1 3 kg<\/td>\n<td>39 \u00b1 3 kg<\/td>\n<td>42 \u00b1 3 kg<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>577 \u00d7 265 \u00d7 512 mm<\/td>\n<td>580 \u00d7 244.5 \u00d7 360 mm<\/td>\n<td>580 \u00d7 244.5 \u00d7 360 mm<\/td>\n<td>580 \u00d7 244.5 \u00d7 360 mm<\/td>\n<\/tr>\n<tr>\n<td>Cooling<\/td>\n<td colspan=\"4\">Air-cooled laser, gas-cooled torch<\/td>\n<\/tr>\n<tr>\n<td>Operating environment<\/td>\n<td colspan=\"4\">0\u201340 \u00b0C, 10\u201385 % RH, &lt; 2,000 m, overvoltage cat. II, pollution degree 2<\/td>\n<\/tr>\n<tr>\n<td>Shielding gas<\/td>\n<td colspan=\"4\">Argon or nitrogen, 99.996 %, 0.8\u20131.5 bar, 12\u201315 l\/min<\/td>\n<\/tr>\n<tr>\n<td>Laser class<\/td>\n<td colspan=\"4\">Class 4, 1070\u20131090 nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Questions before delivery? Contact THEO support or your distributor. Five minutes on your outlet and gas setup saves a day of waiting.<\/p>","protected":false},"excerpt":{"rendered":"<p>Minden, aminek a hely\u00e9n kell lennie, miel\u0151tt meg\u00e9rkezik a THEO MA1 Series: l\u00e9zerbiztons\u00e1gi ter\u00fclet, k\u00fcl\u00f6n \u00e1ramk\u00f6r \u00e9s csatlakoz\u00f3 (EU\/US), v\u00e9d\u0151g\u00e1z \u00e9s nyom\u00e1sszab\u00e1lyoz\u00f3, ajt\u00f3reteszel\u00e9s, f\u00fcstelsz\u00edv\u00e1s.<\/p>","protected":false},"author":958,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"doc_category":[127,396],"doc_tag":[],"class_list":["post-16722","docs","type-docs","status-publish","hentry","doc_category-theo-ma1-knowledge","doc_category-tutorials"],"acf":[],"year_month":"2026-11","word_count":1546,"total_views":"51","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"claude_restapi","author_nicename":"claude_restapi","author_url":"https:\/\/go.theo.inc\/hu\/blog\/author\/908fb14138ca16e880831b2922186cd9\/"},"doc_category_info":[{"term_name":"THEO Knowledge Base","term_url":"https:\/\/go.theo.inc\/hu\/manuals-category\/theo-ma1-knowledge\/"},{"term_name":"Tutorials","term_url":"https:\/\/go.theo.inc\/hu\/manuals-category\/tutorials\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/docs\/16722","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/users\/958"}],"replies":[{"embeddable":true,"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/comments?post=16722"}],"version-history":[{"count":2,"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/docs\/16722\/revisions"}],"predecessor-version":[{"id":17386,"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/docs\/16722\/revisions\/17386"}],"wp:attachment":[{"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/media?parent=16722"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/doc_category?post=16722"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/go.theo.inc\/hu\/wp-json\/wp\/v2\/doc_tag?post=16722"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}