{"id":16149,"date":"2025-11-05T06:46:31","date_gmt":"2025-11-05T06:46:31","guid":{"rendered":"https:\/\/go.theo.inc\/?post_type=docs&#038;p=16149"},"modified":"2026-09-30T09:52:41","modified_gmt":"2026-09-30T09:52:41","password":"","slug":"handheld-torch-protective-cover-slide-replacements","status":"publish","type":"docs","link":"https:\/\/go.theo.inc\/es\/knowledge-base\/handheld-torch-protective-cover-slide-replacements\/","title":{"rendered":"Tutoriales THEO MA1 Series | Cambio de los cristales protectores de la pistola"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><strong>Issue Date:\u00a0Nov. 4th, 2025<br>Memo Number: TB.MP.11425A<br>Revision: 1<br>Products Affected:\u00a0All Handheld Laser Systems<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Tools:<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Masking Tape<\/li>\n\n\n\n<li>Nitrile Gloves<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Instructions<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The following Instructions are intended to guide in the replacement of the protective cover slide (window) in all Theo handheld laser systems. These instructions will reduce contamination of the focusing lens and all other torch optical components.<\/p>\n\n\n\n<p class=\"has-luminous-vivid-amber-background-color has-background has-medium-font-size wp-block-paragraph\"><strong>Note: <\/strong>Establish a proper workspace of at least 1.5 meters around the unit. Make sure area is free of traffic and all lock-out tag-out procedures have been followed. Use proper PPE where needed.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"margin-top:2em;margin-bottom:2em\"><img decoding=\"async\" width=\"504\" height=\"452\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2025\/11\/image.png\" alt=\"\" class=\"wp-image-10223\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Gather all materials and tools needed to perform repair&nbsp;<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Low pressure air<\/li>\n\n\n\n<li>Power free gloves<\/li>\n\n\n\n<li>70% IPA wipes<\/li>\n\n\n\n<li>Protective slide (Window)<\/li>\n\n\n\n<li>Kapton tape<\/li>\n\n\n\n<li>Masking tape (Painter\u2019s tape)<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Note the fiber bend radius at back of torch to ensure no less than&nbsp;<strong>20cm<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"margin-top:2em;margin-bottom:2em\"><img decoding=\"async\" width=\"504\" height=\"348\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2025\/11\/image-1.png\" alt=\"\" class=\"wp-image-10224\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Seal torch tip with masking tape<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Blow entire torch off with low pressure air to remove any loose particles<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Wear dust mask while using compressed air<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Put on gloves<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Only use power free gloves when handling optics<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use IPA and particle free cloth to clean&nbsp;<strong>entire<\/strong>&nbsp;torch outer surface or 70% IPA cleanroom wipes<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Set torch horizontally on flat surface<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Never replace optics with torch cavity facing up<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Do not run gas through the torch during optics replacement<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\" style=\"margin-top:2em;margin-bottom:2em\"><img decoding=\"async\" width=\"504\" height=\"440\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2025\/11\/image-2.png\" alt=\"\" class=\"wp-image-10225\" style=\"width:800px;height:auto\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Cut a piece of Kapton tape long enough to cover the protective slide opening<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Place tape above slide opening<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Never use any other tape other than Kapton tape around optics<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"margin-top:2em;margin-bottom:2em\"><img decoding=\"async\" width=\"504\" height=\"408\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2025\/11\/image-3.png\" alt=\"\" class=\"wp-image-10226\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Unscrew the thumb screw for the protective slide counterclockwise<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The screw is captive and does not need to be entirely removed<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Carefully break seal, stop, and remove entire slide assembly by pulling outward<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Do not pull quickly as this will draw a vacuum<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"margin-top:2em;margin-bottom:2em\"><img decoding=\"async\" width=\"504\" height=\"514\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2025\/11\/image-4.png\" alt=\"\" class=\"wp-image-10227\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Use your thumb of the hand supporting the torch to seal the open cavity with Kapton tape immediately after slide housing removal<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Push protective slide and sealing ring out of housing<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use low pressure air to clean particle from slide housing<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"margin-top:2em;margin-bottom:2em\"><img decoding=\"async\" width=\"504\" height=\"354\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2025\/11\/image-5.png\" alt=\"\" class=\"wp-image-10228\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Use IPA and particle free cloth to clean&nbsp;<strong>entire<\/strong>&nbsp;slide housing outer surface or 70% IPA cleanroom wipes<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"margin-top:2em;margin-bottom:2em\"><img decoding=\"async\" width=\"504\" height=\"382\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2025\/11\/image-7.png\" alt=\"\" class=\"wp-image-10237\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Install new slide with seal facing outward while the slide housing faces vertically as shown<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do not expose the slide to falling particles<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do not touch the face of the slide (even with gloves)<\/p>\n\n\n\n<p class=\"has-luminous-vivid-amber-background-color has-background wp-block-paragraph\"><strong>Never try to clean a protective slide\u00a0<\/strong> <br><strong>Always replace with new as the cost of the slide is not worth potential risks<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\" style=\"margin-top:2em;margin-bottom:2em\"><img decoding=\"async\" width=\"504\" height=\"512\" src=\"https:\/\/go.theo.inc\/wp-content\/uploads\/2025\/11\/image-6.png\" alt=\"\" class=\"wp-image-10229\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Slowly remove Kapton tape to expose slide cavity<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Reinstall slide assembly in torch<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Screw the thumb screw clockwise to gently tighten<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Do not over tighten<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Clean work area and resume operation<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Issue Date:\u00a0Nov. 4th, 2025Memo Number: TB.MP.11425ARevision: 1Products Affected:\u00a0All Handheld Laser Systems Tools: Instructions The following Instructions are intended to guide in the replacement of the protective cover slide (window) in all Theo handheld laser systems. These instructions will reduce contamination of the focusing lens and all other torch optical components. Note: Establish a proper workspace [&hellip;]<\/p>\n","protected":false},"author":651,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"doc_category":[127,396],"doc_tag":[227,226],"class_list":["post-16149","docs","type-docs","status-publish","hentry","doc_category-theo-ma1-knowledge","doc_category-tutorials","doc_tag-laser-welding","doc_tag-ma1-series"],"acf":[],"year_month":"2026-11","word_count":433,"total_views":"44","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"Anthony Tabor","author_nicename":"anthony-tabor","author_url":"https:\/\/go.theo.inc\/es\/blog\/author\/9d9c305310357cc9ce3256d88c34248b\/"},"doc_category_info":[{"term_name":"THEO Knowledge Base","term_url":"https:\/\/go.theo.inc\/es\/manuals-category\/theo-ma1-knowledge\/"},{"term_name":"Tutorials","term_url":"https:\/\/go.theo.inc\/es\/manuals-category\/tutorials\/"}],"doc_tag_info":[{"term_name":"Laser Welding","term_url":"https:\/\/go.theo.inc\/es\/manuals-tag\/laser-welding\/"},{"term_name":"MA1 Series","term_url":"https:\/\/go.theo.inc\/es\/manuals-tag\/ma1-series\/"}],"_links":{"self":[{"href":"https:\/\/go.theo.inc\/es\/wp-json\/wp\/v2\/docs\/16149","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/go.theo.inc\/es\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/go.theo.inc\/es\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/go.theo.inc\/es\/wp-json\/wp\/v2\/users\/651"}],"replies":[{"embeddable":true,"href":"https:\/\/go.theo.inc\/es\/wp-json\/wp\/v2\/comments?post=16149"}],"version-history":[{"count":0,"href":"https:\/\/go.theo.inc\/es\/wp-json\/wp\/v2\/docs\/16149\/revisions"}],"wp:attachment":[{"href":"https:\/\/go.theo.inc\/es\/wp-json\/wp\/v2\/media?parent=16149"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/go.theo.inc\/es\/wp-json\/wp\/v2\/doc_category?post=16149"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/go.theo.inc\/es\/wp-json\/wp\/v2\/doc_tag?post=16149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}